Sign in →

Test Code LAB268 CSF CULTURE, AEROBIC

Important Note

Includes gram stain

Performing Laboratory

 

Mohawk Valley Health System Laboratory

Day(s) Performed

Performed: Daily

Routine TAT: 4 Days

 

Specimen Type

CSF

Collection Container

CSF tube

Specimen Collection and Handling

CSF is collected in sterile, leak-proof, screw top tubes. Deliver to the laboratory immediately CSF specimens should be collected via lumbar puncture, and should not be centrifuged, diluted, or otherwise processed prior to testing.

 

CSF Collection tube # 3 is the preferred tube; otherwise submit the most turbid tube to microbiology. Submit to laboratory as soon as possible. 
 

CSF should be delivered to laboratory within 1 hour of specimen collection. CSF will not be rejected if received after the 1-hour collection time limit; however, a time delay will be noted on the final report. Do not refrigerate specimens.
 

Notes

False-positive results can result from contamination of the specimen with skin micro biota.
False-negative results can be caused by low numbers of organisms, prior anti-microbial treatment or the fastidious nature of the infective organism.