Test Code LAB10006 CT/GC AMPLIFIED DNA ASSAY
Performing Laboratory
Mohawk Valley Health System Laboratory
Day(s) Performed
Performed: Daily
Routine TAT: Same Day
Available as a STAT test
Specimen Type
Vaginal Swab, Throat Swab, Rectal Swab, Urine
Collection Container
Swab: Aptima Multitest Swab
Urine: Sterile container; Sterile cup
Specimen Collection and Handling
Female Patients: Preferred sample type to be tested using Clinician or Patient collected Vaginal swab using the Aptima Multitest Specimen Collection Kit; alternatively, may test Urine specimen collected in sterile cup.
Male Patients: Specimen type is Urine specimen collected in sterile cup.
Male and Female Patients: May also use the Aptima Multitest Specimen Collection Kit for testing Throat swabs and Rectal swab if necessary.
Refer to policy MVHS Laboratory Hologic Aptima Specimen Collection Guides LAI 2340 for further information
Swabs: room temperature (15-30 °C) or refrigerated (2–8 °C) up to 60 days.
Urine: Urine specimens that are still in the primary collection container must be transported to the lab at 2°C to 30°C. Transfer the urine specimen into the Aptima urine specimen transport tube or to laboratory within 24 hours of collection.
Notes
1. The presence of mucus in endocervical specimens does not interfere with the detection of CT or GC by the AC2 assay. However, to ensure collection of cells infected with CT,columnar epithelial cells lining the endocervix should be sampled. If excess mucus is not removed, sampling of these cells is not ensured.
2. Vaginal swab specimen sampling is not designed to replace cervical exams and endocervical specimens for diagnosis of female urogenital infections. Patients may have cervicitis, urethritis, urinary tract infections, or vaginal infections due to other causes or concurrent infections with other agents.
3. The AC2 assay is not intended for the evaluation of suspected sexual abuse or for other medico-legal indications. For those patients for whom a false positive result may have adverse psycho-social impact, the CDC recommends retesting.
4. Therapeutic failure or success cannot be determined with the AC2 assay since nucleic acid may persist following appropriate antimicrobial therapy.
5. Results from the AC2 assay should be interpreted in conjunction with other laboratory and clinical data available to the clinician.
6. A negative result does not preclude a possible infection because results are dependent on adequate specimen collection. Test results may be affected by improper specimen collection, technical error, specimen mix-up, or target levels below the assay limit of detection.
7. Patient-collected vaginal swab specimens are an option for screening women when a pelvic exam is not otherwise indicated. The patient-collected vaginal swab specimen application is limited to clinical settings where support/counseling is available to explain procedures and precautions. The AC2 assay has not been validated for use with vaginal swab specimens collected by patients at home.
8. First catch female urine specimens are acceptable but may detect up to 10% fewer CT/GC infections when compared with vaginal and endocervical swab specimens.